Associação do desempenho do teste de velocidade da marcha com o teste de caminhada de 6 minutos em indivíduos com dpoc

dc.contributor.authorSilva, Teresa Verônica Oliveira
dc.contributor.authorCamelier, Fernanda Warken Rosa
dc.date.accessioned2023-08-01T12:47:27Z
dc.date.available2023-08-01T12:47:27Z
dc.date.issued2018
dc.description.abstractOBJETIVO: Avaliar a associação do desempenho no teste de velocidade da marcha (TVM) de 10m com o desempenho no teste de caminhada de 6 minutos (TC6) em indivíduos com DPOC. MATERIAL E MÉTODOS: Tratou-se de um estudo descritivo de corte transversal com indivíduos com DPOC de ambos os sexos atendidos em um ambulatório de pneumologia de um hospital de referência em Salvador-Bahia. A avaliação foi composta por testes funcionais (TVM e TC6) e por instrumentos para avaliar variáveis clínicas de sintomas respiratórios (questionário CAT e escala de dispneia do MRC). Os dados foram analisados no SPSS e aplicou-se o coeficiente de correlação de Pearson com significância estatística considerando um p < 0,05. RESULTADOS: A amostra foi composta por 44 indivíduos, sendo 56,8% do sexo masculino, com idade média de 67,1 ± 9,2 anos. Os valores de média de velocidade da marcha foram 1,30±0,26m/s no TVM1, 1,34±0,28m/s no TVM2 e 1,36±0,29m/s no TVM3 e todos os avaliados tiveram bom desempenho. A média da distância percorrida no TC6 foi de 398,1±87,4m. Houve associação entre o desempenho no TVM1, TVM2 e TVM3 e no TC6, a saber: r = - 0,663; r – 0,691; e r = - 0,681 respectivamente (p = 0,0001). CONCLUSÃO: Os resultados obtidos pelo presente estudo sugerem que o TVM e o TC6 possuem associação positiva entre si e que ao lado de testes já utilizados, o TVM pode ser um valoroso instrumento de medida de capacidade funcional.
dc.description.abstract2OBJECTIVE: To evaluate association between 10m Gait Speed Test (GST) performance and 6-minute walk test (6MWT) performance in COPD individuals. MATERIALS AND METHODS: The crosssectional descriptive study in COPD individuals of both sexes assisted in a pneumology ambulatory in a well-referenced hospital Salvador-Bahia. The evaluation was composed by functional tests (GST and 6MWT) and by instruments to evaluate clinical variations of respiratory symptoms (CAT survey and Medical Research Council dyspnea scale). The data were analyzed in SPSS and the Pearson´s correlation coefficient was applied with statistical significance considering p < 0.05. RESULTS: The sample was composed by 44 individuals, being 56.8% the masculine sex, with an average age of 67.1 ± 9.2 years old. The average gait speed values were 1.30±0.26m/s for GST1, 1.34±0.28m/s for GST2, and 1.36±0.29m/s for GST3 and all individuals evaluated showed good performance. Average walk distance in 6MWT equaled 398.1±87.4m. There was an association between performance in GST1, GST2, and GST3 and in 6MWT, considering: r = - 0.663; r – 0.691; and r = - 0.681 respectively (p = 0.0001). CONCLUSION: The results obtained by the present study suggest that GST and 6MWT present positive association among each other and that alongside other tests already used, GST can be a valuable instrument in measuring functional capacity. OBJECTIVE: To evaluate association between 10m Gait Speed Test (GST) performance and 6-minute walk test (6MWT) performance in COPD individuals. MATERIALS AND METHODS: The crosssectional descriptive study in COPD individuals of both sexes assisted in a pneumology ambulatory in a well-referenced hospital Salvador-Bahia. The evaluation was composed by functional tests (GST and 6MWT) and by instruments to evaluate clinical variations of respiratory symptoms (CAT survey and Medical Research Council dyspnea scale). The data were analyzed in SPSS and the Pearson´s correlation coefficient was applied with statistical significance considering p < 0.05. RESULTS: The sample was composed by 44 individuals, being 56.8% the masculine sex, with an average age of 67.1 ± 9.2 years old. The average gait speed values were 1.30±0.26m/s for GST1, 1.34±0.28m/s for GST2, and 1.36±0.29m/s for GST3 and all individuals evaluated showed good performance. Average walk distance in 6MWT equaled 398.1±87.4m. There was an association between performance in GST1, GST2, and GST3 and in 6MWT, considering: r = - 0.663; r – 0.691; and r = - 0.681 respectively (p = 0.0001). CONCLUSION: The results obtained by the present study suggest that GST and 6MWT present positive association among each other and that alongside other tests already used, GST can be a valuable instrument in measuring functional capacity.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://saberaberto.homologacao.uneb.br/handle/123456789/4712
dc.identifier2.Lattes2442519436792985
dc.identifier2.Lattes5178884736999846
dc.language.isopt_BR
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subject.keywordsTeste de velocidade da marcha
dc.subject.keywordsTeste de caminhada de 6 minutos
dc.subject.keywordsDPOC
dc.titleAssociação do desempenho do teste de velocidade da marcha com o teste de caminhada de 6 minutos em indivíduos com dpoc
dc.typeinfo:eu-repo/semantics/article
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Associação do desempenho do teste_Teresa Silva.pdf
Tamanho:
408.28 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
462 B
Formato:
Item-specific license agreed upon to submission
Descrição: